Научная литература
booksshare.net -> Добавить материал -> Медицина -> Джордж А.Г. -> "Анестезия и педиатрия" -> 981

Анестезия и педиатрия - Джордж А.Г.

Джордж А.Г. Анестезия и педиатрия — М.: Медицина, 2003. — 1192 c.
ISBN 5-225-03821-2
Скачать (прямая ссылка): anesteziyavpedeatrii2003.djvu
Предыдущая << 1 .. 975 976 977 978 979 980 < 981 > 982 983 984 985 986 987 .. 1012 >> Следующая

1992
161. Eyer S, Brummitt C, Crossley K, et al: Catheter-related sepsis: prospective, randomized study of three methods of long-term catheter maintenance. Crit Care Med 18:1073,
1990
162. Lee RB, Buckner M, Sharp KW: Do multi-lumen catheters increase central venous catheter sepsis compared to single-lumen catheters? J Trauma 28:1472, 1988
163. Downs JB, Douglas ME: Assessment of cardiac filling pressure during continuous positive pressure ventilation. Crit Care Med 8:285, 1980
164. Vender JS: Resolved: a pulmonary artery catheter should be used in the management of the critically ill patient. Pro. (review). J Cardiothorac Vase Anesth l2(Suppl l):9, 1998
165. Becker К Jr Resolved: a pulmonary artery catheter should be used in the management of the critically ill patient. Con. [review). J Cardiothorac Vase Anesth l2(Suppl
I): 13, 1998
166. Teboul JL, Zapol WM, Bntn-Buisson C, et al: A comparison of pulmonary artery occlusion pressure and left ventricular end-diastolic pressure during mechanical ventila-tion with PEEP in patients with severe ARDS. Anesthesiology 70:261, 1989
167. Freed MD, Keane JF: Cardiac output measured by thermodilution in infants and children. ) Pediatr 92:39, 1978
168. Jansen JR, Schreuder JJ, Bogaard JM, et al: Thenmudilu-tion technique for measurement of cardiac output during artificial ventilation. ) Appl Physiol 51:584, 1981
169. Stevens JH, Raffin ТА, Mihm FG, et al: Thermodilution cardiac output measurement: efTects of the respiratory cycle on its reproducibility. JAMA 253:2240, 1985
170. Filioux F, Dean JM, Kirsch JR: Monitoring the central nervous system, p. 667. In Rogers MC (ed): Textbook of Pediatric Intensive Care. 3nd Ed. Williams & Wilkins, Baltimore, 1996
I7|. Greenberg RP, Ward JD, Lutz H, et al: Advanced monitoring of the brain, p. 67. In Grenvilc A, Safer P (eds): Clinics in Critical Care Medicine: Brain Failure and Resuscitation. Churchill Livingstone, New York, 1981
172. Sloan ТВ: Neurologic monitoring. Crit Care Clin 4:543, 1988
173. Saul TG, DuckerTB: Effect of intracmnial pressure monitoring and aggressive treatment on mortality in severe head injury. J Neurosurg 56:498, 1982
174. Rogers AT, Stump DA: Cerebml physiologic monitoring. Crit Care Clin 5:845, 1989
|75. Poss WB, Brockmeyer DL, Clay B, et al: Pathophysiology aud management of the intracranial vault. In Rogers MC, Nichols DG (eds): Textbook of Pediatric Intensive Care. Beltimore, Williams A Wilkins, 1996, p 645
176. Tasker RC, Matthew DJ: Cerebml intraparenchymal pressure monitoring in non-traumatic coma: clinical evaluation of a new fibreoptic device. Neuropediatrics 22:47,
1991
177. Gamlatrdella G, Zaccone C, Cardia E, et al: Intmcrania) pressure monitoring in children: comparison of external ventricular device with the fiberoptic system. Childs Nerv Syst 9:470, 1993
178. Miudermann T, Reinhardt H, Gmtzl O: Significant lateralization of supratentorial ICP after blunt head trauma. Acta Neurochir 116:60, 1992
179. Cascino GD: Neurophysiological monitoring in the intensive care unit. J Intensive Care Med 3:215, 1988
180. Veselis RA, Reinsel R, Alagesan R, et al: The EEG as a
monitor of midazolam amnesia: changes in power and topography as a (unction of amnesic state. Anesthesiology 74:866, 1991
181. Fisher B, Peterson B, Hicks G: Use of bminstem auditory evoked response testing to assess neurologic outcome following near drowning in children. Crit Care Med 20:578,
1992
182. Goodwin SR, Friedman WA, Bellefleur M: Is it time to use evoked potentials to predict outcome in comatose children and adults? Crit Care Med 19:518, 1991
183. Reid KH, Mullins ER, Iyer VG: Changes in brainstem auditory evoked response latency predict survival after CPR in a rat model of cardiac arrest and resuscitation. Resuscitation 36:65, 1998
184. Ruiz-Lopez MJ, deAzagra AM, Serrano A, et al: Brain death and evoked potentials in pediatric patients. Crit Care Med 27:412, 1999
185. Flannery AM: Brain death and evoked potentials in pediatric patients. Crit Care Med 27:264, 1999
186. Moulton RJ, Brown Jl, Konasiewicz SJ: Monitoring severe heud injury: a comparison of EEG and somatosensory evoked potentials. Can J Neurol Sci 25:S7, 1998
187. Konasiewicz SJ, Moulton RJ, Shedden PM: Somatosensory evoked potentials and intracmnial pressure in severe head injury. Can J Neurol Sci 21:219, 1994
188. Brazy JE: Cerebral oxygen monitoring with near infrared spectroscopy: clinical application to neonates. J Clin Monit 7:325, 1991
189. Edwards AD, Brown GC, Cope M, et al: Quantification of concentration changes in neonatal human cerebral oxidized cytochrome oxidase. J Appl Physiol 71:1907,
1991
190. von Siebenthal K, Bemert G, Casacr P: Near-infrared spectroscopy in newborn infants. Brain Dev 14:135, 1992
191. Faris F, Rolfe P, Thomiley M et a|: Non-invasive optical monitoring of carebral blood oxygenation in the foetus and newborn: preliminary investigation. J Biomed Eng 14:303,
Предыдущая << 1 .. 975 976 977 978 979 980 < 981 > 982 983 984 985 986 987 .. 1012 >> Следующая

Реклама

c1c0fc952cf0704ad12d6af2ad3bf47e03017fed

Есть, чем поделиться? Отправьте
материал
нам
Авторские права © 2009 BooksShare.
Все права защищены.
Rambler's Top100

c1c0fc952cf0704ad12d6af2ad3bf47e03017fed