Научная литература
booksshare.net -> Добавить материал -> Медицина -> Джордж А.Г. -> "Анестезия и педиатрия" -> 305

Анестезия и педиатрия - Джордж А.Г.

Джордж А.Г. Анестезия и педиатрия — М.: Медицина, 2003. — 1192 c.
ISBN 5-225-03821-2
Скачать (прямая ссылка): anesteziyavpedeatrii2003.djvu
Предыдущая << 1 .. 299 300 301 302 303 304 < 305 > 306 307 308 309 310 311 .. 1012 >> Следующая

1. Cullen SC: Anesthesia: Year Boole Med Anesthesiol 28:396, 1967
2. Eisselle J, Trenchant D, Stubbs J et al: The immediate cardiac depression by anaesthetics in conscious dogs. Br J Anaesth 41:86, 1969
3. Cooper JO. Cullen BF: Observer reliability in detecting surreptitious random occlusions of the monaural esophageal stethoscope. I Clin Monit 6.271 1990
4. Van R, Arts CM, Hopman 1C et al: The influence of respiratory distress syndrome on heart rate variability in very
Sreterm infants. Early Hum Dev 27:207, 1991 lutlolph AM: Congenital Heart Disease. Year Book Medical Publishers, Chicago, 1974
6. Bruner JMR: Hazards of electrical appaitus. Ал improved standard blood pressure cuff size. Clin Pediatr 15:784.
1976
7. Nicodemus HF. Nassiri-Rahimi C, Bachman L, Smith TC: Median effective dose (EDW) of halothane in adults and children. Anesthesiology 31:344. 1969
8. Dias J H, Lockhart CH: Is halothane really safe in infancy? Anesthesiology 5I.S3I3, 1979
9. Friesen RH, Henry DB: Cardiovascular changes in preterm neonates receiving isoflurane, halothane, fentanyl, and ketamine. Anesthesiology 64:238, 1986
10. Myung K, Kawabori I, Guntheroth WG: Need for an im-
Мониторинг во время операции 343
proved standard blood pressure cuff size. Clin Pediatr 15:784, 1976
11. Burch GE, Shewey L: Sphygmomanometric cuff size and blood pressure recordings. JAMA 225:1215. 1973
12. Hill GE, Machin RH: Doppler determined blood pressure recordings: the effect of varying cuff sizes in children. Can Anaesth Soc J 73:323, 1976
13. Ramsey M III: Noninvasive blood pressure monitoring methods and validation, p. 37. In Gruvcnstein JS, New-bauer RS, Ream A К et al (eds): Essential Noninvasive Monitoring in Anesthesia. Grune & Stratton, Orlando, 1980. p.37
14. Park MK, Menard SM: Accuracy of blood pressure measurement by the Dinamap monitor in infants and children. Pediatrics 79:907, 1987
15. Spirtazzola RM, Harper RG de SM. Lesser M: Blood pressure values in 500- to 750-gram birthweight infants in the first week of life. J Perinatol 11:147, 1991
16. Hochbeig HM, Saltzman MB: Accuracy of an ultrasound blood pressure instrument in neonates, infants and children. Curr Ther 13:482, 1971
17. Waltemath CL, Preuss DD: Determination of blood pressure in low-flow states by the doppler technique. Anesthesiology 34:77, 1971
18. Kltterman JA, Phibbs RH, Toolcy WH: Catheterization of umbilical vessels in newborn infants. Pediatr Clin North Am 17:895. 1970
19. Pearse RG: Percutaneous catheterization of the radial artery in newborn babies using transillumination. Arch Dis Child 53:549, 1978
20. Butt WW, Gow R. Whyte H et al: Complications resulting from use of arterial catheters: retrograde flow and rapid elevation of blood pressure. Pediatrics 76:250. 1985
21. Dahl MR, Smead WL, McSweeucy TD: Radial artery cannulation: a comparison of 1.52- and 4.45-cm catheters. J Clin Monit 8:193, 1992
22. Tollner U, Bechinger D, Pohlandt F: Radial nerve palsy in a premature infant following long-term measurement of blood pressure. J Pediatr 96:921. 1980
23. Hack WW, Vos A, van der Lei J, Okken A: Incidence and duration of total occlusion of the radial artery in newborn infants after catheter removal. Eur J Pediair 149:275, 1990
24. Rais-Buhrami K, Kama P. Dolanski EA: Effcct of fluids on life span of peripheral arterial lines. Am J Perinatol 7:122, 1990
25. Gardner RM: Direct blood pressure measurements — dynamic response requirements. Anesthesiology 54:227, 1981
26. Brown DR, Fenton U, Tsang RC: Blood sampling through umbilical catheters. Pediatrics 55:227. 1975
27. Miyasaka K, Edmonds JF, Conn AW: Complications of radial artery lines in the paediatric patient. Can Anaesth Soc J 23:9, 1976
28. Saladino R, Bachman D, Fleischer G: Arterial access in the pediatric emergency department. Ann Emcig Med 19:382, 1990
29. Lowenstein E. Little JW. Lo HH: Prevention of cerebral embolization from flushing radial artery cannulas. N Engl J Med 285:1414, 1971
30. Thibeault DW, Emmanuilides GC: Patent ductus aneroi-sus complicating the respiratory distress syndrome in preterm infants. J Pediatr 86:120. 1975
31. Schick JB, Beck AL, DeSilva HN: Umbilical artery catheter position and intraventricular hemorrhage і Perinatol 9.382, 1989
32. Kemply ST, Gamsu H R: Randomised trial of umbilical arterial position: Doppler ultrasound findings. Arch Child 67:855, 1992
33. Kitterman JA: Fatal air embolism through an umbilical venous catheter. Eur J Pediatr 131:71, 1979
34. Hoffman JIE, Buckberg GI>. The myocardial supply-de-mand ratio: a critical review. Am J Cardiol 41:327. 1978
344 Анестезия в педиатрии
35. Goldstein RF, Brazy JE: Fluctuations of arterial blood pressure decrease with mechanical ventilation in premature infants with respiratory distress syndrome. J Perinatol 10:267, 1990
36. Rudolph AM, Drorbaugh JE, Auld PAM et al: Studies on the circulation in the neonatal period: the circulation in the respiratory distress syndrome. Pediatrics 27:551, 1961