29. Plenum Press, New York, 1980.
16. Higgins I.J., Hill H.A.O., Plotkin E.V. Measurement of enzyme
catalysed reactions. European Patent 125137, 14th Nov. 1984.
17. Ikeda Т., Hamada H., Miki K., Senda M. Glucose oxidase immobilised
benzoquinone-carbon paste electrode as a glucose sensor. Agric. Biol.
Chem. (Japan), 49, 541-3 (1985).
88 Глава 6
18. Ikeda Т.. Katasho I.. Kamei М., Senda M. Electrocatalysis with a
glucose oxidase immobilized graphite elecrode. Agric. Biol. Chem.
(Japan), 48, 1969-76 (1984).
19. Jonsson U., Malmqvist М., Ronnberg I. Immobilization of immuno
globulins in silica surfaces: stability for use as immunosensor and in
affinity chromatography. Biochem. J., 227, 363-71 (1985).
20. Kawaguri М., Nankai S., Iijima T. Biosensor. PCT Int. App. W08403562,
13 Sept. 1984.
21. Kennedy J.F., Barker S. A., Rosevear A. Preparation of water
insoluble trans-2,3-cyclic carbonate
' derivative of macroporous cellulose and its use as a matrix for enzyme
immobilisation. J. Chem. Soc.
Perkin; 2293-9 (1973).
22. Kimura S., Hayano Т., Kato K. Properties and applications to
immunoassay of monoclonal antibodies to neuron specific yy enolase.
Biochem. Biophys. Acta, 799, 252-9 (1984).
'23. Киек C., Armitage T.M. Scanning electronmicroscopic examination of
calcium alginate beads immobilizing growing mycelia. Enz. Microb.
Technol., 7, 121-5 (1985).
24. Masoom М.. Townshend A. Simultaneous determination of sucrose and
glucose in mixtures by flow injection analysis with immobilized enzymes-
invertase/mutarotase column and glucose oxidase column. Anal. Chim. Acta,
171, 185-94 (1985).
25. Matsushita. Biosensor. Japan Kokai Tokkyo Koho JP 59 67, 452, 17th
April, 1984.
26. Matsushita. Biosensor. Japan Patent 011896, 4th August, 1984.
27. Mattiassin B., Danielsson B. Calorimetric analysis of sugars and
sugar derivatives with aid of an enzyme thermistor. Carb. Res., 102, 273-
82 (1982).
28. Miyawaki O., Wingard L.B. FAD and glucose oxidase immobilised on
carbon. Ann. N. Y. Acad. Sci., 434, 520 2 (1984).
29. Mosbach K. Immobilized coenzymes in ligand affinity chromatography
and their use as active coenzymes. Advances in Enzymology, 46, 205-78
(1978).
30. Mozes N.. Rouxhet P. G. Dehydrogenation of cortisol by Arthrobacter
simplex immobilized as supported monolayer. Enz. Microb. Technol., 6,
497-502 (1984).
31. Ngo T.T., Lenhojf H.M. Amperometric assay for collagenase.
Amplification by use of GOD conjugated to insoluble collagen. Appl.
Biochem. Biotechnol,, 8, 407-14 (1983).
32. Nikolelis D. P. Construction of an immobilised asparaginase sensor
and determination of asparagine in blood serum. Anal. Chim. Acta, 161,
343-8 (1984).
33. North J.R. Immunosensors: antibody based biosensors-comparison of
construction methods and devices. U.K. Trends Biotechnol., 3, 180-6
(1985).
34. Okada Т., Karube I., Suziki S. N02 sensor which uses immobilized
nitrite oxidising bacteria. Biotechnol. Bioeng., 25, 1641-51 (1983).
35. Romette J.L., Boitieux J.L. Oxidase enzyme: enzyme and immunoenzyme
sensor - computerized automatic system development: glucose oxidase
application. Ann. N. Y. Acad. Sci., 434, 533-5 (1984).
36. Romette J. L., Yang J. S., Kusakabe H" Thomas D. Enzyme electrode for
specific determination of L-lysine. Biotechnol. Bioeng., 25, 2557-66
(1983).
37. Sonawot H. М., Phadke R. S., Govil G. Covalent immobilization of FAD
and glucose oxidase on carbon electrodes using cyclic voltammetry.
Biotechnol. Bioeng., 26, 1066-70 (1984).
38. Szuminsky N.J., Chen A. K., Liu С. C. A miniature Palladium-Palladium
oxide enzyme electrode for urea determination. Biotechnol. Bioeng., 26,
642-5 (1984).
39. Tokinaga D., Kobavashi Т., Katori A.. Karasawa Y. Urease immobilised
urea electrode and process for preparing the same. U.S. Patent 4, 476,
005, Oct. 9th, 1984. Hitachi Ltd.
40. Tokyo Elec. Enzyme electrode containing immobilised glucose oxidase
or uricase with enzyme store for supplementation. JP 224055, 24th June.
1985.
41. Tran N.D., Romette J.L.. Thomas D. An enzyme electrode for specific
determination of L-lysine. A real time sensor. Biotech. Bioeng., 25, 329-
40 (1983).
42. Tsuchida Т., Takasugi II.. Yoda K., Takizawa K., Kobayashi S.
Application of L-lactate electrode for clinical analysis and monitoring
of tissue culture medium-an enzyme electrode for L-lactic acid
determination. Biotechnol. Bioeng., 27, 837 - 41 (1985).
43. Verdyuyn C., Van Dijken J.P., Schejfers W.A. A simple sensitive and
accurate alcohol electrode. Biotechnol. Bioeng., 25, 1049-55 (1983).
44. Van Haecht J. L., De Bremaeker М., Rouxhet P. G. Immobilization of
yeast by adhesion to a support without use of a chemical agent. Enzym.
Microbiol. Technol, 6, 221-7 (1984).
45. Wingard L. B., Cantin L.A., Castner J.F. Effect of enzyme matrix
composition on potentiometric response to glucose using glucose oxidase
immobilised on Platinum. Biochim. Biophys. Acta, 748, 21 -7 (1983).