fluorescence indicator molecules measuring pH and p02 down to
submicroscopial regions on the basis of the optode principle. Z.
Naturforsch., 32c. 133-4 (1977).
12. MacDonald B. F., Seitz W. R. Tetrakis N-dimethylaminoethylene is an
extraordinarily sensitive reagent for oxygen. Anal. Lett., 15(A 1), 57-66
(1982).
13. Milanovich F.P., Hirschfield T. B.. Wang F.T.. Klainer S.M. Clinical
measurements using fiber optics and optrodes. Proc. SPIE-Int. Soc. Opt.
Engl., 494, 18-24 (1984).
14. Opitz N., Luebbers D. W. Simultaneous measurement of blood gases by
means of fluorescence indicators. Pfluegers Arch., 362, R52 (1976).
15. Opitz N. New fluorescence photometrical techniques for simultaneous
and continuous measurements of ionic strength and hydrogen ion
activities. Sensors and Actuators, 4, 473-9 (1983).
16. Opitz N. A correction method for ionic strength-independent
fluorescence photometric pH measurement. Adv. Exp. Med. Biol., 169, 907-
12 (1984).
17. Peterson J.L, Vurek G.G. Fiber optic sensors for biomedical
applications. Science, 224, 123-7 (1984).
18. Opitz N.. Fitzgerald R. V., Buckhold D. K. A fiber-optic pO , sensor
for phvsiological use. Anal. Chem., 56,62-7 (1984).
19. Peterson J. L, Goldstein S. R., Fitzgerald R. V, Buckhold D. K. Fiber
optic pH probe for physiological use. Anal. Chem., 52, 864-9 (1980).
20. Saari L.A., Seitz W.R. pH sensor based on immobilized
fluoresceinamine. Anal. Chem., 54, 821 -3
(1982).
21. Saari L. .4. Immobilized morin as fluorescence sensor for
determination of aluminium (III). Anal. Chem., 55, 667-70 (1983).
22. Schultz J.S., Sims G. Affinity sensors for individual metabolites.
Biotechnol. Bioeng. Symp., 9, 65 -71 (1979).
23. Schultz J. S.. Mansoure S., Goldstein I. J. Affinity sensor: A
technique for developing implantable sensors for glucose and other
metabolites. Diabetes Care, 5D, 245-53 (1982).
24. Seitz W.R. Chemical sensors based on fiber optics. Anal. Chem., 56,
16A (1984).
25. Seitz W. R., Saari L. A., Zhujun Z., Pokornicki S., Hudson R.D.,
Sieber S. C., Ditzler M. A. Metal ion
Оптические сенсоры на основе иммобилизованных реагентов
487
sensors based on immobilized fluorogenic ligands. In Advances in
Luminescence Spectrometry (eds. L. J. Cline Love, D. Eastwood), pp. 63-
77. ASTM Pub. no. 863, Philadelphia, 1985.
26. Sepaniak M.J., Tromberg B.J., Eastham J.F. Optical fiber fluoroprobes
in clinical analysis. Clin. Chem., 29, 1678-82 (1983).
27. Sutherland R. М., Daehne C., Place J. F. Preliminary results obtained
with a no-label homogeneous, optical immunoassay for human immunoglobulin
G. Anal. Lett., 17, 43-53 (1984).
28. Sutherland R.M., Ringrose A. S. Optical detection of antibody-antigen
reactions at a glass-liquid interface. Clin. Chem., 30, 1533-8 (1984).
29. Urbano E., Ojfenbacher IF, Wolfbeis O. S. Optical sensor for
continuous determination of halides. Anal. Chem., 56, 427-9 (1984).
30. Uwira N" Opitz N.. Luebbers D. W. Influence of enzyme concentration
and thickness of the enzyme layer on the calibration curve of the
continuously measuring glucose optode. Adv. Exp. Med. Biol., 169, 913-21
(1984).
31. Voelkl K.P., Optiz N.. Luebbers D. W. Continuous measurement of
concentrations of alcohol using a fluorescence-photometric enzymatic
method. Fres. Z. Anal. Chem., 301, 162-3 (1980).
32. Vurek G. G., Feustel P. J., Severinghaus J.W. A fiber optic pC02
sensor. Annals of Biomed. Eng.,11, 499-510 (1983).
33. Wolfbeis O.S., Fuerlinger F., Kroneis IF, Marsoner H. Fluorimetric
analysis. 1. A study of fluorescent indicators for measuring near neutral
('physiological') pH-values. Fres. Z. Anal. Chem., 314, 119-24
(1983).
34. Wolfbeis O. S., Ojfenbacher H., Kroneis H" Marsoner H. A fast
responding fluorescence sensor for oxygen. Mikrochimica Acta, 153-8
(1984).
35. Zhujun Z., Seitz W. R. A fluorescence sensor for quantifying pH in
the range from 6.5 to 8.5. Anal. Chim. Acta, 160, 47-55 (1984).
36. Z.hujun Z. A carbon dioxide sensor based on fluorescence. Anal. Chim.
Acta, 160, 305 -9 (1984).
Глава 31
Перспективы применения био- и хемилюминесценции в биосенсорах
Ф. Мак-Капра
31Л. Введение
Из дискуссий о концепции биосенсоров, особенно в этой коллективной
монографии, очевидно, что существует несколько подходов. Наиболее
универсальный заключается в использовании материалов биологического
происхождения, таких, как целые клетки, ферменты или иммуноглобулины для
первичного контакта с определяемым веществом. Возникающие при этом
проблемы являются общими для всех биосенсоров, и мы их обсуждать не
будем. С другой стороны, методы обработки сигналов хорошо развиты, и
часто требуется только миниатюризация или адаптация этих методов для
конкретных целей.
В центре проблемы биосенсоров находятся преобразователи, переводящие
биохимические процессы в электронные эффекты или электрические сигналы.
Преобразователи -широкое поле деятельности для изобретателей и людей с
Предыдущая << 1 .. 267 268 269 270 271 272 < 273 > 274 275 276 277 278 279 .. 355 >> Следующая

Реклама

c1c0fc952cf0704ad12d6af2ad3bf47e03017fed

Есть, чем поделиться? Отправьте
материал
нам
Авторские права © 2009 BooksShare.
Все права защищены.
Rambler's Top100

c1c0fc952cf0704ad12d6af2ad3bf47e03017fed